Richmond water heater pilot light won - Replace the pilot assembly, I do water heater repair, that unit is actually made by A.O. Smith. It’s got a 180 pilot assembly. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete.

 
We have a Rheem gas water heater model number 21V40-7P. We've just gotten the gas tank refilled, but for some reason, the pilot light went out this morning and the water heater is leaking. I'm trying … read more. Lurie

New Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ...Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air ConditioningIf your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ...Mar 4, 2022 · A water heater pilot lights but not the burner if the thermostat is damaged or over 10 years old. Flame sensors can fail if they are dislodged and the burner won’t detect the pilot light’s flame. Your water heater’s burner won’t work if the gas valve is damaged or the thermostat is unresponsive. Water heater problems often require ... I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a...The pilot on my Rheem furnace will not stay lit. I have replaced the thermocouple to no avail. The flame looks perfect, nice and blue, the thermocouple gets glowing hot when attempting to light the pilot. I hold the button down in excess of 3 minutes and as soon as you release, the pilot light goes out immediatly.Begin by turning your pilot light off, if it is not already. Next, turn off the flow of gas to your furnace completely using the shutoff valve. It should be nearby or even on your furnace. Once you have done this, allow your furnace to cool down for at least 30 minutes so it is safe to open, then open the hatch covering your pilot light and ...I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.For use on GE, Rheem, Ruud and Richmond FVIR water heaters with Delta/SIT gas valves; Genuine OEM replacement part; 1 year limited warranty; Fix your water heater with peace of mind using genuine Rheem parts; Easy to install; Call 1-800-432-8373 to ensure this is the correct part for your water heater; Durable construction for long lifeI am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ...Have you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ...It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. No hot water? If the pilot flame in your water heater keeps on going out or won't stay lit, then it could be a problem with the thermocouple or thermal cutof...If the pilot will not stay lit on your gas water heater, then this is likely to be the problem.If the pilot will not stay lit on your gas water heater, then this is likely to be the problem.I have a Richmond electronic iginition water heater model 5VP40E-1A, sometimes it lights and and works for a few days, sometimes I have to shut it down and then re-start it to get it to work, seen oth …I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v...A water heater pilot light that won’t stay lit is almost always caused by a bad thermocouple. It fails to send a signal to the gas valve to open up, meaning gas does no flow to the pilot and burner. It could also be caused by a faulty gas control valve or tripped thermal switch. If your water heater pilot won’t stay lit even after replacing ...Remove the access panel to access the burner. Turn the knob to “Pilot” to start the flow of gas. You’ll want to press and hold the knob down. While still holding the gas knob, light the pilot with a long lighter. If your gas water heater has an igniting button, press that instead. Once ignited, release and turn the gas knob to the “On ...Power Vent. Uses indoor air for combustion with flexible venting options up to 100 feet. View Product. Gas. Electric. Speciality. I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession.Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup the …Mar 1, 2010 · hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty. If your Richmond water heater pilot light won’t stay lit, you will have trouble getting hot water around the house. So the first thing you should do is check the thermocouple. But if the thermocouple is fine, you should check the other things I mentioned in today’s article.Meet the Most Efficient Water Heater Available Richmond Hybrid Electric Water Heaters Learn More ... Most efficient water heater available – with up to $5,000 in ...5. Flex Tube Defects. This also another possible reason why your pilot’s light won’t come on. The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. This usually happens when the tube is kinked at one or many points. Sep 3, 2018 · I have a Richmond tankless water heater Model # RMTG-74PVN-1. I have a Richmond tankless water heater Model # XXXXX It was installed the summer of 2007. has operated proplem free until last week when it stopped working and flashing C7 on the remote. May 24, 2013 · I am not a professional, just documenting how i repaired the hot water heater's pilot light to stay on. The solution was adjusting the thermocouple. You can ... Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Hi Ellen I have a Richmond 6G30-32F1 gas hot water heater. that stopped working Thursday. the pilot was out so i lit it and tried to turn it on and everytime i tried to turn it on ot wou;d flameup then blow out. so Ive seen this before so I replavedf the thermocouplet/ mo problem. i tried to turn it on and it flamdd uo ran for aminute then cuts off it keeps dpoing this. what is my next step to tryNew Member. May 22, 2013, 08:52 PM. Richmond water heater pilot light won't stay lit. We have a Richmond 40 gal water heater. The sewage pipe in our basement recently overflowed, leaving about 2 inches of water in the basement. Once we got the mess cleaned up, we noticed we have no hot water. We checked the pilot on the hot water heater and ... 01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ...Nov 18, 2022 · The pilot light is an essential part of your Rheem water heater. If it goes out, your water heater wont provide any heat because the pilot light wont ignite the gas to power the heater. This means that you wont be able to light your pilot light. One potential cause of this issue is that you have a blocked gas line. I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit.Step 03 – Drain The Tank. Before taking off the gas valve, you need to drain the water heater. Otherwise, you’ll end up with a mess on your hands. The hot water can also cause scalding. Turn off the cold water shutoff valve if you can locate it or shut off the water supply to your entire house.Install a New Thermocouple. Insert the new thermocouple from the outside through the grommet or opening in the burner assembly manifold cover. Insert the thermocouple into its mounting bracket until it is fully seated or clicks into place. Position the thermocouple tip so that the pilot flame will envelop the top 3/8 to 1/2 inch of the ...Apr 25, 2010 · I could have found the troubleshooting guide by myself. If you replaced the thermocouple and it will not stay lit there are a couple of possibilities. Make sure the pilot flame envelops approximately 3/8 inch of the tip of the new thermocouple. When you go to light make sure you continue to hold down the button at least 30 seconds after the ... Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... Reopen the shutoff valve. Relight the pilot light. Turn the control valve to “on”. When the gas burner comes on, use a 50/50 dish soap/water mix to test the screw joints for air bubbles that indicate leaks. Note: When relit, the water heater pilot light flame should wrap around the thermocouple bulb.Last night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...Feb 15, 2021 · If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ... Install a New Thermocouple. Insert the new thermocouple from the outside through the grommet or opening in the burner assembly manifold cover. Insert the thermocouple into its mounting bracket until it is fully seated or clicks into place. Position the thermocouple tip so that the pilot flame will envelop the top 3/8 to 1/2 inch of the ...Access the pilot light: Depending on the model of your water heater, you may need to remove a metal panel to access the pilot light. Once you have access, locate the pilot light and the reset button. Press the reset button: Press and hold the reset button for 30-60 seconds.Jan 15, 2023 · Step 03 – Drain The Tank. Before taking off the gas valve, you need to drain the water heater. Otherwise, you’ll end up with a mess on your hands. The hot water can also cause scalding. Turn off the cold water shutoff valve if you can locate it or shut off the water supply to your entire house. It is more than likely some kind of high limit sensor which would kick the pilot out should the water heater overheat. If your pilot is not staying lit with a new thermocouple, it may be this sensor. Try jumping the 2 leads going to the thermocouple adapter and see if it remains lit. If it does, it is this sensor that is bad.If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ...Dec 22, 2022 · Pilot light won't stay lit. Richmond 6G40-36F3 Installed 7/2021. ... My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after ... Jun 17, 2018 · my water heater won't stay on If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve).Usually, the pilot light isn’t staying lit on a Richmond water heater due to the bad thermocouple. It may also be due to a lack of combustible air, but this is less likely. Look to see if the thermocouple has been bent, damaged, or is too dirty, and take appropriate action.Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's lit A.O. Smith GVR 40 101 water heater had no spark on the pilot. Disassembled and cleaned the pilot light and thermocouple. Reassembled and fired it up on the f...Reopen the shutoff valve. Relight the pilot light. Turn the control valve to “on”. When the gas burner comes on, use a 50/50 dish soap/water mix to test the screw joints for air bubbles that indicate leaks. Note: When relit, the water heater pilot light flame should wrap around the thermocouple bulb.Replaced Pilot assembly last week as pilot went out when burner shut off. Today I replaced the temperature control valve. Same thing, lit pilot, burner came on the after a heat cycle burner shut off as well as pilot. Trying an immediate restart only igniter worked after about 4 or 5 minutes was able to light the pilot. Then the whole episode ... 01 - Water Heater Gas Valve and Thermostat Assembly. The gas valve opens to allow gas to enter the burner. If the gas valve does not open, the burner will not light. First, ensure that the ignition source is working properly. Second, ensure that the gas valve has pressure. If the ignition source is working, and the gas valve has pressure ...Jul 29, 2023 · Richmond Water Heater Pilot Light Won’t Stay Lit: A Detailed Discussion. As you can see from the table above, there are many reasons why the heater’s pilot light tends not to stay lit. And there are solutions for each problem. In the following part, I have discussed the issues in more detail and also shared how you can solve them. Water heater,,,,6G40S34F3,,,pilot light won't stay lite. 4 years about. Richmond. Just happened today - Answered by a verified HVAC TechnicianTurn the gas off on the main shutoff valve that is supplying a water heater. Remove the cover plate at the bottom of the water heater, if possible. Locate the pilot tube connected to the gas valve with the nut and disconnect it. There is also a thermocouple attached. If needed, disconnect it too.The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ...Water heater pilot won't light. Richmond water heater, smelled for gas at end of tibe by burner and is present. Filter isn't clogged. Ignition sparks. ...Jan 17, 2021 · I installed a new Richmond water heater and worked good for like 4 - 5 days. then pilot light went and when i would try to ignite, pilot light would light but as soon as i replaced thermocoupler did t … read more I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit.Aug 5, 2020 · Water Heaters - Weird AO Smith Nat Gas Pilot light issue - I have two 2006 AO Smith 40-gal ProMax gas hot water heaters. I have taken very good care of them, I flush them once a year, change the anode rods as needed, keep them clean, check for backdrafting, etc. Last week one of them had a pilot light out and wouldn't I had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession. Feb 15, 2021 · If your hot water heater has no spark at all, or the flame isn't staying on, give this video a watch for a couple super simple things to try. Repairing your ... It’s also a relatively inexpensive component. So, you won’t have to break the bank to replace it. You can check out our guide on why Richmond water heater pilot light won’t stay lit where we have broken down how to replace the thermocouple in nice and easy steps. 6. Faulty Pressure SwitchWater heater,,,,6G40S34F3,,,pilot light won't stay lite. 4 years about. Richmond. Just happened today - Answered by a verified HVAC TechnicianMay 7, 2023 · If you have a Richmond water heater model 6G40-36F3 and you notice that the pilot light won't stay lit, you may be wondering what is causing this problem and how to fix it. In this blog post, we will explain some of the possible reasons why your pilot light keeps going out and what you can do to solve them. Apr 25, 2010 · I could have found the troubleshooting guide by myself. If you replaced the thermocouple and it will not stay lit there are a couple of possibilities. Make sure the pilot flame envelops approximately 3/8 inch of the tip of the new thermocouple. When you go to light make sure you continue to hold down the button at least 30 seconds after the ... Sep 25, 2021 · Have you tried cleaning/replacing your thermocouple and still no dice? Have you tried cleaning/replacing the pilot assembly and still nothing? My opinion is ... Dec 31, 2015 · 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective. The water heater pilot light is a small flame that ignites the gas burner on your water heater. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is ... It’s also a relatively inexpensive component. So, you won’t have to break the bank to replace it. You can check out our guide on why Richmond water heater pilot light won’t stay lit where we have broken down how to replace the thermocouple in nice and easy steps. 6. Faulty Pressure SwitchThe Richmond Marathon ® water heater offers a LIFETIME warranty. The Marathon is a special water heater that has a seamless blow molded polybutene inner tank. It will not rust. The several inches of foam insulation give it up to 0.93 uniform energy factor. Tank sizes range from 15 gallons to 105 gallons to fit any household need. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light.RickyM1118. Plumber. High School or GED. 29 satisfied customers. My seven year old Richmond 6G40-32PF1 lp gas water heater. My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won't stay lit after releasing button. The gas tank ran out of gas and was … read more.Last night, I noticed that the pilot light was out and this morning when the plumber came to look at it he immediately told me what was wrong with it which is the gas control valve is bad. Said it would cost about $700 to fix so I called Menards and the plumbing associate informed me that the Richmond water heaters have a recall on them for ...Sep 14, 2022 · 1. There Is Residual Gas Inside the Unit. Before attempting to ignite your water heater's pilot light, it is important that you turn the gas off and let the unit sit for at least five minutes. This allows any residual gas to disperse from the lines and inside the unit. You don't actually need to shut off the gas valve. Dec 31, 2015 · 2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective. Review Hoffmann Brothers' guide for how to light your water heater pilot light, perform basic checks, troubleshoot and access info for your specific brand. Careers (314) 664-3011 Book Now Air Conditioning

2. If I understand correctly, your pilot flame is lighting correctly. But the main burner won't turn on because the electronics in the Gas Control Valve don't acknowledge the pilot is lit. There are two likely faults: Thermopile is not sensing the flame correctly, or. Circuit Board in the Gas Control Valve is defective.. Therapists

richmond water heater pilot light won

Turn the gas off on the main shutoff valve that is supplying a water heater. Remove the cover plate at the bottom of the water heater, if possible. Locate the pilot tube connected to the gas valve with the nut and disconnect it. There is also a thermocouple attached. If needed, disconnect it too.Jan 5, 2006 · Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out. Apr 9, 2020 · I'm not a professional. This is the one thing that's worked AMAZING to get my hot water heater pilot light to stay on! INCREDIBLE prices on AMAZON: https://a... Jun 17, 2018 · my water heater won't stay on If the pilot won't stay lit after you release the button/knob you hold down to light it then the first thing that needs to be done is to replace the pilot flame sensor, thermocouple (heavy bare copper wire connected to the gas valve) or the thermopile (small shielded cable with 2 wires connected to the gas valve).I am posting this video as there are many videos on YouTube explaining what to do if your pilot light doesn't remain on after igniting, but couldn't find a v...Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions … read morePress and hold down on the gas control knob, or pilot set button. At the same time as you’re holding down the pilot switch, press on the piezo igniter. When you click the igniter, you should hear a “click” sound, indicating the spark igniting the pilot. Once the pilot light is on, continue pressing down on the pilot switch for a minute to ...Jan 5, 2006 · Here is what to try. First, using the back end of a large screw driver, medium hard tap the gas control valve. Doing so may dislodge the tiny disk and the pilot will go out. If not, try again. If second attempt fails, turn off the control knob. Turn control dial to the OFF position, so the pilot does go out. We have a Rheem gas water heater model number 21V40-7P. We've just gotten the gas tank refilled, but for some reason, the pilot light went out this morning and the water heater is leaking. I'm trying … read moreI had a power outage at my house and coincidentally (?) my water heater pilot light went out. My Kenmore water heater is controlled by the Honeywell Gas Valve (part # 9007884), which contains the WV8840 Communication Port. The water heater wouldn’t re-light, but I noticed that the indicator was blinking four times in succession. hayewe farm · #2 · Mar 1, 2010. Go to your local hardware or computer store and pick up a can of air used to clean computer keyboards. With the pilot off insert the air can tube in the end of the pilot tube and give it a couple of blasts of air. It may be you have an oxygen depletion unit that is dirty.My seven year old Richmond 6G40-32PF1 lp gas water heater pilot light won’t stay lit after releasing button. The gas tank ran out of gas and was refilled. It is a sealed system with a window to view the pilot light.Richmond water heaters have a warranty that is specific to your water heater. The warranty varies based on the model. Some models, like the Marathon, have lifetime warranties, while others have a 6- or even a 12-year warranty.Apr 24, 2011 · I have a Richmond 5v40-7 water heater, we had a flood and I waitted sometime before lighting the polit light.The polit light worked fine, but when I turned up the dial from vacation to warmer after a few minute I would notice some smoke coming from the back of the control unit. Water heater pilot is not on; no hot water. Serial No. Q132038894. Model No. 6G40-36F3. I've tried to start the pilot light without success. The instructions affixed on the heater and the instructions for lighting do not match my heater: I see no door to open; no place to see the pilot to determine if it's litJun 15, 2017 · So I have a 40 gal Richmond power vent lp water heater. Problem is it doesn't restart So far I have replaced the igniter .I took out the whole water heat and cleaned out the combustion chamber and … .